FRACTURE LOAD OF SILVER SOLDERED JOINTS ON STAINLESS STEEL AND COBALT-CHROMIUM ORTHODONTIC WIRES WITH VARIOUS JOINING CONFIGURATIONS

Main Article Content

Pradeep Subbaiah
Ravi S
Raghunath N

Abstract

The current research compared and analysed the tensile strength of silver soldered stainless steel and cobalt-chromium orthodontic wire joints with band material The effect of joint site planning on various orthodontic joining configurations was investigated. A total of sixty wire specimens were chosen, thirty in the stainless-steel group and thirty in the cobalt – chromium group. Again, each group's sample was divided into three subgroups, namely End – End, Round, and Orthodontic band material. The study findings suggested all three configurations can be used to make silver soldered joints regardless of the wire consistency. When subjecting the wire to joint site planning, however, stainless steel wire should be used with its limitations in mind.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Article Details

How to Cite
Subbaiah, P. ., S, R., & N, R. . (2021). FRACTURE LOAD OF SILVER SOLDERED JOINTS ON STAINLESS STEEL AND COBALT-CHROMIUM ORTHODONTIC WIRES WITH VARIOUS JOINING CONFIGURATIONS. American International Journal of Sciences and Engineering Research, 4(1), 26–35. https://doi.org/10.46545/aijser.v4i1.210
Section
Original Articles/Review Articles/Case Reports/Short Communications
Author Biographies

Pradeep Subbaiah, JSS Academy of Higher Education and Research, India

Lecturer

Department of Orthodontics & Dentofacial Orthopaedics

JSS Academy of Higher Education and Research, India

Ravi S, JSS Academy of Higher Education and Research, India

Associate Professor

Department of Orthodontics & Dentofacial Orthopaedics

JSS Academy of Higher Education and Research, India

Raghunath N, JSS Academy of Higher Education and Research, India

Professor & HOD

Department of Orthodontics & Dentofacial Orthopaedics

JSS Academy of Higher Education and Research, India

References

Brown, T., Mitchell, R., & Barenie, J. (1982). Evaluation of five silver soldering techniques. The Journal of pedodontics, 6(3), 235-243.

Cattaneo, G., Wagnild, G., Marshall, G., & Watanabe, L. (1992). Comparison of tensile strength of solder joints by infrared and conventional torch technique. The Journal of prosthetic dentistry, 68(1), 33-37.

Chaves, M., Vermilyea, S. G., Papazoglou, E., & Brantley, W. A. (1998). Effects of three soldering techniques on the strength of high-palladium alloy solder joints. The Journal of prosthetic dentistry, 79(6), 677-684.

Cheng, A. C., Chai, J. Y., Gilbert, J., & Jameson, L. M. (1994). Investigation of stiffness and microstructure of joints soldered with gas-oxygen torch infrared methods. The Journal of prosthetic dentistry, 72(1), 8-15.

Cheng, A. C., Chai, J. Y., Gilbert, J., & Jameson, L. M. (1993). Mechanical properties of metal connectors soldered by gas torch versus an infrared technique. Journal of Prosthodontics, 2(2), 103-109.

Dua, R., & Nandlal, B. (2004). A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material—an in vitro study. J Indian Soc Pedod Prev Dent, 22, 13-6.

Gawlik, J. A., Mathieu, G. P., & Hondrum, S. (1996). The effects of tack welding and increasing surface area on the tensile strength of silver electric and flame soldered stainless steel joints. Pediatric dentistry, 18, 215-218.

Gardiner, J. H., & Aamodt, A. C. (1969). Some aspects of soldering stainless steel. A metallurgical investigation. The Dental practitioner and dental record, 20(2), 65-76.

Gulker, I. A., Martini, R. T., Zinner, I. D., & Panno, F. V. (1994). A comparison of hydrogen/oxygen and natural gas/oxygen torch soldering techniques. International Journal of Prosthodontics, 7(3).

Laird, W. R., & Von Fraunhofer, J. A. (1972). Silver soldered joints in stainless steel. A comparative evaluation of techniques. British dental journal, 132(7), 263-267.

O'Toole, T. J., Furnish, G. M., & Von Fraunhofer, J. A. (1985). Tensile strength of soldered joints. The Journal of prosthetic dentistry, 53(3), 350-352.

Phillips, R. W. (1991). Wrought base metal alloys wrought gold alloys. In skinners science of dental materials. Philadelphia: WB Saunders Co, 537-57.

Rogers, O. W. (1979). A metallographic evaluation of the stainless steel-silver solder joint. Australian dental journal, 24(1), 13-16.

Tehini, G. E., & Stein, R. S. (1993). Comparative analysis of two techniques for soldered connectors. The Journal of prosthetic dentistry, 69(1), 16-19.

Verde, M. A. L., & Stein, R. S. (1994). Evaluation of soldered connectors of two base metal ceramic alloys. The Journal of prosthetic dentistry, 71(4), 339-344.

Wiskott, H. W. A., Macheret, F., Bussy, F., & Belser, U. C. (1997). Mechanical and elemental characterization of solder joints and welds using a gold-palladium alloy. The Journal of prosthetic dentistry, 77(6), 607-616.